33-10-06
Page 33-04
Added: July 24, 1981
2F24
CHART 3301. TROUBLESHOOTING (ELECTRICAL SYSTEM) (cont.)
Trouble Cause Remedy
ANNUNCIATOR PANEL (cont.)
VAC warning light fails to Sensor activates at a too Replace.
extinguish. high setting.
Sensor terminals bridged. Remove material between
terminals.
Defective sensor. Replace.
ALT warning light fails to Bulb burned out. Replace.
operate.
No current from bus to Check all wire segments and
resistor. connections.
ALT warning light fails to Blown fuse. Replace 5 amp fuse near the
extinguish. diode heat sink.
No current from the fuse to Check all wire segments and
the resistor. connections.
Test switch fails to activate Bad switch or connections. Check wires and replace
warning lights. switch if necessary.
VAC warning light fails to Bulb burned out. Replace.
operate.
No current to sensor. Check all wire segments and
connections.
Sensor activates at a too Replace.
low setting.
Defective sensor Replace
PIPER AIRCRAFT
PA-28RT-201 / 201T
MAINTENANCE MANUAL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Piper PA-28RT-201 and is the answer not in the manual?

Piper PA-28RT-201 Specifications

General IconGeneral
BrandPiper
ModelPA-28RT-201
CategoryAircrafts
LanguageEnglish

Related product manuals