6.7 Enable or Disable Filter Data Function:
Display will show . Use the [0] key to scroll through the range of
permitted range of choices.
A selected option of NO will disable all CFL and FDF features for this control. No filter event
prompts will occur (Start-up and Trigger Time), an open drain while the control is ON will result
in a controller fault condition, and Oil Life hours will not be tracked.
A selected option of YES will enable all CFL and FDF features described in this manual. This
is the factory default option.
6.8 Enable or Disable Test Function:
Display will show . Use the [0] key to scroll through the range of
permitted range of choices.
If yes, Time values related to the FDF function are “compressed”. Test time for each time value
is total seconds/15. This setting does not change RTC values.
Example: 00:20 min filter time = 1200 seconds, would run as 1200/15 seconds or 1.33 minutes
for test purposes.
Should always be set to NO.
6.9 To Exit FDF Menu:
To exit Factory Programming, Press the key. Display will show .
To return to normal operations, press the
key again.
Display shows
; , or .