Solstice I12 Cooking Computer
Pitco P/N 60149514
Page 5 of 24 L20-379 Rev 0
4
1.4 To cancel a cook:
Press and hold the product key to cancel a running cook. If no other cooks are
pending, controller displays will return to
.
1.5 To check Actual and Set temperatures:
To view the actual vat temperature, press the key. The display will show or
, where “F’ is Fahrenheit, and “C” is Celsius. After a few moments, the display will
return to
; , or , if no cooks are running.
[CKn mm:ss] will display for any cooks still running.
To view the set temperature, press the
key twice. The display will show or
, where “F’ is Fahrenheit, and “C” is Celsius. After a few moments, the display will
return to
; , or , or, [CKn mm:ss] for any cook still
running.
1.6 To View Current Settings for Cook, Shake, Hold, and Hold Pre-Alarm:
To view the current settings for any product key, press the key, followed by the desired
product key. The display will show [CKn mm:ss], followed by [SHn mm:ss], then [HDn mm:ss],
ending with [PAn mm:ss]. Where “n” is the key number, and “mm:ss” is the time setting.
After a few moments, the display will return to
; , or ,
or, [CKn mm:ss] for any cook still running.
Typical displays using key 4 as an example:
Key 4 Cook Time [CK4] is set for 3 minutes and 28
seconds.
Key 4 Shake Time [SH4] is set for 2 minutes and :00
seconds before the end of the Cook. Default value is
00:00, or inactive.
Key 4 Hold Time [HD4] is set for 15:00 minutes. This is
the amount of time cooked product may sit in holding bins
before a new batch is started. Default value is 00:00, or
inactive.
Key 4 Hold Pre-Alarm [PA4] is set for 00:00 and is
inactive (default setting). When activated his alarm
warns the operators that the Hold Time is about to run
out.
In a few moments, the display will return to
.
+
4