6
Industrial Case and Installation
IP30 metal case
DIN rail and wall-mount design
Supports 6000V DC Ethernet ESD protection
-40 to 75 degrees C operating temperature
No external power cable required for installation
Plug and Play installation
Note
PSE (Power Sourcing Equipment) is a device (switch,
or hub for instance) that provides power in a PoE setup.
Maximum allowed continuous output power per such
device in IEEE 802.3af is 15.4W, and in IEEE 802.3at is
30W and in IEEE 802.3bt is 75W.
PD (Powered Device) is a PoE-enabled terminal by
PSE and thus consumes energy, such as PoE IP phones,
PoE IP cameras, PoE wireless access points, etc.