10
Dimensions (H x W x D) 135mm x 87.8mm x 50mm
Weight 631g
Power Requirements
24V or 48V DC for PoE Devices
Redundant power with polarity reverse protection
function
Power Consumption /
Dissipation
66.4 watts / 226BTU max. (PoE)
5.64 watts / 19.24BTU (non-PoE)
Installation DIN Rail Kit and Wall-mount Ear
Standard Conformance
Stability Testing
IEC60068-2-32 (Free Fall)
IEC60068-2-27 (Shock)
IEC60068-2-6 (Vibration)
Operating Temperature -40 ~ 75ºC
Storage Temperature -40 ~ 85ºC
Operating Humidity 10% to 90%, relative humidity, non-condensing
Storage Humidity 10% to 90%, relative humidity, non-condensing
Regulation Compliance FCC Part 15 Class A, CE
Standards Compliance
IEEE 802.3 10Base-T
IEEE 802.3u 100Base-TX
IEEE 802.3af Power over Ethernet
IEEE 802.3x Full duplex pause frame ow control
ITU-T
1. G.997.1
2. G.993.1 VDSL
3. G.993.2 VDSL2 (Prole 17a)
*1. BNC and RJ-11 mode must switch to the same position for Master
and Slave. Otherwise, it may cause unstability.
*2. The actual data rate will vary on the quality of the copper wire and
environment factors.