EXPLOITATION
F-3
MacR6-Z0 USER MANUAL
Battery replacement procedure:
1.
Detach and open the device by removing
six TORX T10 screws from the back of
the cover.
2.
Using strong
magnet or
OptoBTEx
activate the "SEr 4" option.
3.
When activated "bAt
3" information will
appear. Close the
magnet to the
OPTICAL INTERFACE
until the "bAt 0"
information will
appear. Wait until
indicators on the left
side will mute.
4.
"Lo bAt"
information will
appear. Take out the old battery, but do
not place the new one!
5.
When "no bAt"
information will
appear place the new battery. During
this operation the contrast on the
display may be reducing.
Do not let the device to turn off
completely.
6.
New battery
recognition will be
signed by "Hi bAt" information. Battery
level will be set to 100%, and the icon
on display will show the full bar.
7.
Close the cover, place the recorder on
the gas meter. Synchronize the
counters.
It is forbidden to dump the empty batteries with common waste. Empty batteries should be
handed over to the neutralization point according to manufacturers recommendation.