TECHNICAL DATA
B-4
MacR6-Z0 – USER MANUAL
Outside the Ex zone, allowed only for qualified specialists.
Double-band GSM modem 900/2100MHz
External or internal double-band GSM/DCS with 5dBi maximum gain
Optical interface in accordance with IEC 62056-21
Transmission speed 9600 N81
Ambient temperature
range:
-30° ≤ Ta ≤ +55°C
Modem works in full temperatures range
Housing protection level:
Maximum 95% in 55°C temperature
Do not use in vincinity of strong electromagnetic fields sources, or in places
which significantly muffle the GSM signal
136x90x40
136x114x40 (including cable gland)
Gauge or absolute sensor ended with metric M12x1.5 screw
Sensor dimensions: length with cable gland – 92mm, without cable gland –
72mm, diameter – 24mm