24
Hose Clamp
3" Plastic Pipe
Adaptor Rubber Boot
Outer Clamshell Housing
3" x 3" x 2"
DWV Fitting
Piped To
External Air
Supply
Figure 15. Air Inlet Piping
Adaptor
Rubber Boot
Remove
Filter Media
Filter Media shown inside
the Outer Clamshell Housing
Outer Clamshell
Housing
NOTE: if found difficult to
reattach the outer clamshell
housing to the internal clamshell
housing - apply a thin layer of silicone
grease to the surface of the black rubber
support of the Filter Media.
Figure 16. Filter Media
DIRECT VENT AIR INTAKE MOISTURE PROTECTION
7KHDLULQWDNHSLSLQJLQDGLUHFWYHQWV\VWHPZLOOQRUPDOO\QRW
KDYHDQ\PRLVWXUHDFFXPXODWLRQLQLW+RZHYHULQFHUWDLQFDVHV
PRLVWXUHPD\EXLOGXSDQGQHHGVWREHGUDLQHG7\SLFDOVLWXDWLRQV
LQFOXGHEXWDUHQRWOLPLWHGWR
&ROGRXWGRRUWHPSHUDWXUHSDUWLFXODUO\LIWKHDLULQOHWLVVKRUW
+HDWHUEHLQJXVHGPRVWO\IRUVSDFHKHDWLQJ
$LULQOHWSLSHKDVYHUWLFDOULVHQHDUWKHKHDWHUDQG
+LJKRXWGRRUKXPLGLW\
,QVWDOODWLRQVZLWKDQ\RIWKHVHFRQGLWLRQVDUHUHTXLUHGWRSURYLGH
D PRLVWXUH GUDLQ ZLWK D WUDS WKDW ÀRZV WR D ZDVWHGUDLQ 6HH
)LJXUH,QVWDOODGUDLQWHHDVVHPEO\DQGDWUDSLQWKHLQOHW
YHQWDVFORVHWRWKHZDWHUKHDWHUDVSRVVLEOH7KLVLVWRGUDLQDQ\
ZDWHUWKDWPD\EHLQWKHFRPEXVWLRQDLUSLSHDQGSUHYHQWLWIURP
HQWHULQJWKHEORZHU7KHGUDLQWXELQJLQDQ\LQVWDOODWLRQVKRXOG
KDYHDORRSWUDSDQGÀRZWRDQDSSURSULDWHZDVWHGUDLQ7KHDLU
LQWDNHGUDLQOLQHPXVWEHHQWLUHO\VHSDUDWHIURPWKHH[KDXVWYHQW
RXWOHWFRQGHQVDWHOLQH
INSTALL TEE FITTING AS CLOSE TO
WATER HEATER INTAKE AIR
CONNECTION AS POSSIBLE
INTAKE AIR CONDENSATE TEE INSTALLATION
FIELD SUPPLIED
3" x 3" x 1/ 2" TEE
WITH HOSE BARB
FITTING INSTALLED
FACTORY
INTAKE AIR
CONNECTION
INTAKE
AIR
PIPING
CONNECT FIELD
SUPPLIED FLEXIBLE
DRAIN HOSE TO BARB
FITTING AND FORM A
LOOP WATER TRAP IN
DRAIN HOSE
RUN DRAIN HOSE
TO SUITABLE FLOOR
DRAIN SEPARATELY FROM
OTHER CONDENSATE DRAINS
Figure 17
HORIZONTAL VENT TERMINAL INSTALLATION
NOTE: If you are installing your system so that it vents through the
URRISOHDVHUHIHUWR9HUWLFDO9HQW7HUPLQDO,QVWDOODWLRQRQ3DJH
1. After the points of termination have been
GHWHUPLQHG VHH 9HQW3LSH 7HUPLQDWLRQ RQ SDJH 
XVH WKH FRYHU SODWHV DV WHPSODWHV WR PDUN WKH KROHV IRU
WKHYHQWSLSHVWREHLQVHUWHGWKURXJKWKHZDOO%(:$5(2)
CONCEALED WIRING AND PIPING INSIDE OF WALL. If the
YHQWWHUPLQDOVDUHEHLQJLQVWDOOHGRQWKHRXWVLGHRID¿QLVKHG
ZDOOLWPD\EHHDVLHUWRPDUNERWKWKHLQVLGHDQGRXWVLGHZDOO
$OLJQ WKH KROHV E\ GULOOLQJ D KROH WKURXJK WKH FHQWHU RI WKH
WHPSODWHIURPWKHLQVLGHWKURXJKWRWKHRXWVLGH7KHWHPSODWH
FDQ QRZ EH SRVLWLRQHG RQ WKH RXWVLGH ZDOO XVLQJ WKH GULOOHG
KROHVDVDFHQWHULQJSRLQWIRUWKHWHPSODWH
A.) MASONRY SIDE WALLS Chisel an opening approximately
´FPODUJHUWKDQWKHPDUNHGFLUFOH
B.) WOODEN SIDE WALLS Drill a pilot hole approximately
RQH TXDUWHU LQFK RXWVLGH RI WKH PDUNHG FLUFOH7KLV
SLORW KROH LV XVHG DV D VWDUWLQJ SRLQW IRU D VDZVDOO RU
VDEUHVDZEODGH &XW DURXQG WKH PDUNHG FLUFOH VWD\LQJ
DSSUR[LPDWHO\ RQH TXDUWHU LQFK RXWVLGH RI WKH OLQH
7KLV ZLOO DOORZ WKH YHQW SLSH WR HDVLO\ VOLGHWKURXJK
WKH RSHQLQJ 7KH UHVXOWLQJ JDS ZLOO EH FRYHUHG E\ WKH
YHQW WHUPLQDO FRYHU SODWHV 5HSHDW WKLV VWHS RQ WKH
LQVLGHZDOOLIQHFHVVDU\
 &XW D OHQJWK RI SLSH DERXW ´  FP ORQJHU WKDQ WKH
ZDOOWKLFNQHVVDWWKHRSHQLQJ
 *OXHWKHDLULQWDNHWHUPLQDOWRWKHVHFWLRQRIWKHSLSH
 6OLGHWKHZDOOSODWHRYHUSLSHWRVWRSDJDLQVWDLULQWDNHWHUPLQDO
 3ODFHDEHDGRIFDXONLQJQRWVXSSOLHGDURXQGWKHJDSEHWZHHQ
WKH SLSHDQG WKH ZDOO 3ODFH VRPH RI WKH FDXONLQJ RQ WKH
EDFNRIWKHSODWHWRKROGLWDJDLQVWWKHZDOODIWHULQVWDOODWLRQ
 ,IWKHDLULQWDNHSLSHLVLQVWDOOHGXSWRWKHZDOOZLWKDFRXSOLQJRQWKH
HQGDJDLQVWWKHZDOORSHQLQJWKHSLSHZLWKWKHDLULQWDNHWHUPLQDOFDQ
EHSUHSDUHGIRUJOXLQJEHIRUHLQVHUWLQJWKURXJKWKHZDOO6OLGHWKH
SLSHWKURXJKWKHZDOODQGLQVHUWLQWRFRXSOLQJRQWKHRWKHUVLGHRI
WKHZDOO6HH)LJXUHDQG)LJXUH
7.
5HIHUWR)LJXUHLQ³9HQW3LSH7HUPLQDWLRQ´IRUVWDQGDUG DQG
DOWHUQDWHYHQWWHUPLQDWLRQGLPHQVLRQV
8. 5HIHUWR)LJXUHEHORZIRUWKH$OWHUQDWH+RUL]RQWDO7HUPLQDWLRQ
installation.
Figure 18