,IWKH0DLQ%XUQHULJQLWHVPRPHQWDULO\EXWGRHVQRWVXVWDLQLJQLWLRQ
DOORZ WKH ZDWHU KHDWHU WR WU\ WR LJQLWH XS WR WZR PRUH WLPHV XQWLO
FRQWURO V\VWHP ORFNV RXW DQG WKH ,JQLWLRQ )DLOXUH )DXOW PHVVDJH
LV GLVSOD\HG RQ WKH FRQWURO V\VWHPV /&' ,I WKH ZDWHU KHDWHU LV
H[SHULHQFLQJURXJKVWDUWVVHH5RXJK6WDUWLQJ5RXJK2SHUDWLRQ
RQ WKLV SDJH )RU PRPHQWDU\ LJQLWLRQ SUREOHPV ZLWKRXW URXJK
VWDUWLQJFKHFNWKHIROORZLQJ
 8QGHUVL]HGVXSSO\JDVOLQHORZYROXPHRIVXSSO\JDV
 /RZ*DV3UHVVXUH
 6HHWKHOLVWRISRVVLEOHFDXVHVDQGWKLQJVWRFKHFNDQGUHSDLU
for the Ignition Failure Fault message.
 &ORJJHGEORFNHGDLULQWDNHLQWHJUDWHG¿OWHU
 &ORJJHGEORFNHG0DLQ%XUQHU
NOT ENOUGH OR NO HOT WATER
 1RSRZHUWRWKHZDWHUKHDWHUFKHFNEUHDNHUIXVHV
 (QDEOH'LVDEOH VZLWFK LQ ³GLVDEOHG´ SRVLWLRQ 6HW WR HQDEOH WR
DOORZXQLWWRRSHUDWH
 +RWZDWHUVXSSO\YDOYHVWR¿[WXUHVFORVHG
 2SHUDWLQJ6HW3RLQWLVVHWWRRORZ'LIIHUHQWLDOVHWWLQJLVVHWWRR
high.
 7HPSHUDWXUH3UREH2IIVHWVHWWLQJDUHFDXVLQJWKHKHDWLQJF\FOHV
to terminate prematurely.
 7KHKHDWLQJFDSDFLW\RIWKHZDWHUKHDWHUKDVEHHQH[FHHGHG
WKHZDWHUKHDWHULVXQDEOHWRPHHWGHPDQG
 &ROGHU LQFRPLQJ ZDWHU WHPSHUDWXUH OHQJWKHQLQJ WKH WLPH
UHTXLUHGWRKHDWZDWHUWRGHVLUHGWHPSHUDWXUH
 +RWZDWHUSLSLQJOHDNVRSHQIDXFHWVZDWHUKHDWHUGUDLQYDOYH
OHDNLQJRURSHQ6HH/HDNDJH&KHFNSRLQWVRQ3DJH
 6HGLPHQW RU OLPH VFDOH DFFXPXODWLRQ PD\ EH DIIHFWLQJ ZDWHU
heater operation.
WATER IS TOO HOT
Operating Set Point is set too high. See Operating Set Point
DQG'LIIHUHQWLDO$GMXVWPHQWRQ3DJH
Temperature Probe Offset settings improperly set. See
2SHUDWLQJ6HW3RLQWDQG'LIIHUHQWLDO$GMXVWPHQWRQ3DJH
,I LQVWDOOHG FKHFN 7KHUPRVWDWLF 0L[LQJ 9DOYH VHWWLQJV 6HH
Mixing Valves on Page 18.
/LPHEXLOGXSRQWHPSHUDWXUHSUREHV
NOISY OPERATION
 1RUPDORSHUDWLQJQRLVHRIHOHFWULFDOFRPSRQHQWV&RPEXVWLRQ
%ORZHUWUDQVIRUPHUKXPUHOD\FRQWDFWFORVXUH
REPLACEMENT PARTS
5HSODFHPHQW SDUWV PD\ EH RUGHUHG IURP WKH PDQXIDFWXUHU
DXWKRUL]HG VHUYLFH DJHQFLHV RU GLVWULEXWRUV :KHQ RUGHULQJ SDUWV
EHVXUHWRKDYHWKHFRPSOHWHZDWHUKHDWHU0RGHO1XPEHU6HULDO
1XPEHU DQG 6HULHV 1XPEHU DYDLODEOH 7KLV LQIRUPDWLRQ FDQ EH
IRXQGRQWKHUDWLQJSODWHDI¿[HGWRWKHZDWHUKHDWHU
)RUPRUHLQIRUPDWLRQRUWHFKQLFDOVXSSRUWFDOOWKHWHFKQLFDOVXSSRUW
SKRQHQXPEHUOLVWHGRQWKHEDFNFRYHURIWKLVPDQXDO
OPERATIONAL PROBLEMS
Read and understand this instruction
manual and the safety messages
herein before installing, operating or
servicing this water heater.
Failure to follow these instructions and
safety messages could result in death
or serious injury.
This manual must remain with the
water heater.
7KLVVHFWLRQ RI WKH PDQXDO LVLQWHQGHG WREH DQDLG LQ FRUUHFWLQJ
FRPPRQRSHUDWLRQDOSUREOHPVLWLVQRWDOOLQFOXVLYH7KHLQVWDOOHU
PD\EHDEOHWRREVHUYHDQGFRUUHFWFHUWDLQSUREOHPVZKLFKPLJKW
DULVH ZKHQ WKH ZDWHU KHDWHU LV ¿UVW SXW LQWR RSHUDWLRQ RU ZKHQ LW
LV UH¿UHG DIWHU D SURORQJHG VKXWGRZQ +RZHYHU RQO\ TXDOL¿HG
VHUYLFHWHFKQLFLDQ VKRXOG SHUIRUP DQ\ VHUYLFH SURFHGXUHV RQWKH
ZDWHUKHDWHU
NOTE:&DOOWKHWHFKQLFDOVXSSRUWSKRQHQXPEHUOLVWHGRQWKHEDFN
FRYHURIWKLVPDQXDOIRUIXUWKHUWHFKQLFDODVVLVWDQFHRUWRORFDWHD
TXDOL¿HGVHUYLFHWHFKQLFLDQLQ\RXUDUHD
ROUGH STARTING, ROUGH OPERATION
Fire and Explosion Hazard
Excessive gas pressure to gas control
valve can cause serious injury or death.
Do not use water heater with any gas
other than the gas shown on the rating
plate.
Turn off gas lines during installation.
Contact a qualified installer or service
technician for installation and service.
 8QGHUVL]HGVXSSO\JDVOLQHORZYROXPHRIVXSSO\JDV
 /RZ*DV3UHVVXUH
 ([FHVVLYHVXSSO\JDVSUHVVXUH
 ([FHVVLYHPDQLIROGRIIVHWJDVSUHVVXUH
 ,QFRUUHFW)XHO7\SH
 9HQWH[KDXVWJDVUHFLUFXODWLRQDWWKHYHQWDQGLQWDNHDLUSLSH
WHUPLQDWLRQVRQ'LUHFW9HQWLQVWDOODWLRQV
 ([FHVVLYHHTXLYDOHQWOHQJWKVRILQWDNHDLUDQGRUYHQWH[KDXVW
SLSLQJLQVWDOOHG
 &ORJJHGEORFNHGDLULQWDNHLQWHJUDWHG¿OWHU
 &ORJJHGEORFNHGWKH0DLQ%XUQHU
MOMENTARY IGNITION
Burn Hazard
Do not reach into the burner housing or
combustion chamber if the water heater
is still hot.
Allow the water heater to cool and always use
gloves when handling the main burner.
The combustion chamber and burner sleeve
and housing become very hot during operation.
CAUTION

Questions and Answers: