39
TEMPERATURES (CONT)
DESCRIPTION/ACTION DISPLAY
• Differential$GMXVWDEOHXVHUVHWWLQJWKDWFKDQJHVWKHWDQN
WHPSHUDWXUHGLIIHUHQWLDOZLWKDUDQJHRIWR)7KHIDFWRU\
VHWWLQJLV)
• Tank Probe OffsetDGMXVWDEOHXVHUVHWWLQJUDQJHWR)
IDFWRU\VHWWLQJ)
NOTE: 7KHVHVHWWLQJVVKRXOGRQO\EHXVHGLIWKHKRWZDWHUVXSSO\
temperature varies greatly from the Operating Set Point setting.
7KH 7DQN 3UREH 2IIVHW LV XVHG WR FDOLEUDWH FRQWURO V\VWHP
WHPSHUDWXUH VHQVLQJ 7KLV FDQ LPSURYH WKH SUHFLVLRQ RI
WHPSHUDWXUH FRQWURO LQ WKH VWRUDJH WDQN DQG DW SRLQWV RI XVH
7KLV IHDWXUH FDQ DOVR EH XVHG WR FRPSHQVDWH IRU EXLOGLQJ
UHFLUFXODWLRQORRSVKRWZDWHUUHWXUQLQJWRWKHVWRUDJHWDQNWKDW
PD\FDXVHWKHKHDWLQJF\FOHVWRWHUPLQDWHSUHPDWXUHO\
([DPSOH ,I WKH FXUUHQW VHQVHG WHPSHUDWXUH IURP D
WHPSHUDWXUH SUREH LV ) & DQG WKH 2IIVHW VHWWLQJ LV
DGMXVWHG WR D YDOXH RWKHU WKDQ ) WKH FRQWURO V\VWHP ZRXOG
FDOLEUDWH RU ³RIIVHW´ WKH VHQVHG WHPSHUDWXUH IURP WKH SUREH
DQG WKH DYHUDJHG WDQN WHPSHUDWXUH +HDWLQJ F\FOHV ZRXOG
EH DFWLYDWHG DQG GHDFWLYDWHG EDVHG RQ WKH FDOLEUDWHG RIIVHW
WHPSHUDWXUH$)VHWWLQJUHVXOWVLQ)KRWWHUZDWHU
7KHVH VHWWLQJV DUH DGMXVWHG LQ WKH VDPH ZD\ GHVFULEHG IRU
2SHUDWLQJ6HW3RLQW$QG'LIIHUHQWLDO$GMXVWPHQWRQSDJH
Temperatures
HELPBACK
Operating Setpoint 120°F >
Differential 8°F >
Tank Probe Offset 0°F >
HEATER STATUS MENU
DESCRIPTION/ACTION DISPLAY
Press Heater Status from the Main Menu to enter this menu. This
PHQX FRQWDLQV QRQ DGMXVWDEOH RSHUDWLRQDO LQIRUPDWLRQ 8VH WKH
VOLGHEDUWRQDYLJDWHWKHPHQX
• StatusGLVSOD\VWKHFXUUHQW2SHUDWLQJ6WDWHVHH7DEOH
on page 37.
• ECO Contact, Blocked Inlet PS, Blocked Outlet PS -
GLVSOD\VWKHFXUUHQWVWDWHRIWKHVZLWFKFRQWDFWVRSHQRU
FORVHG
• Igniter On, Gas Valve OnGLVSOD\VZKHWKHURUQRWWKH
FRQWUROV\VWHPLVFXUUHQWO\HQHUJL]LQJWKHVHZDWHUKHDWHU
FRPSRQHQWV\HV HQHUJL]HGQR GHHQHUJL]HG
• Flame DetectedGLVSOD\VZKHWKHURUQRWWKHFRQWUROV\VWHP
KDVGHWHFWHG0DLQ%XUQHUÀDPHGXULQJLJQLWLRQIURPWKH
ÀDPHVHQVRU
• Blower RPM CMDGLVSOD\VWKHFRQWUROVFRPPDQGHG
EORZHU530
• Blower RPM GLVSOD\VWKHDFWXDOEORZHU530
NOTE:7KH PHQX GLVSOD\ LV VKRZQ ZLWK WKH (QDEOH'LVDEOH
VZLWFKLQ(QDEOHGSRVLWLRQDQGWKHZDWHUKHDWHULVLQ6WDQGE\
PRGH :KHQ WKH (QDEOH'LVDEOH VZLWFK LV LQ WKH 'LVDEOHG
SRVLWLRQWKHZDWHUKHDWHUZLOOEHLQ³:DWHU+HDWLQJ'LVDEOHG´
PRGH
NOTE:
7KH PHQX GLVSOD\V VKRZQ DUH IRU LQIRUPDWLRQDO
SXUSRVHVRQO\7KHDFWXDOKHDWHUGLVSOD\ZLOOYDU\GHSHQGHQW
XSRQWKHRSHUDWLRQDOVWDWHRIWKHZDWHUKHDWHU
Top of Menu
Heater Status
HELPBACK
Status: Standby
ECO Contact Closed
Blocked Inlet PS Closed
Blocked Outlet PS Closed
Igniter On No
Bottom of Menu
Heater Status
HELPBACK
Gas Valve On No
Flame Detected No
Blower RPM CMD 0
Blower RPM 0