51
FAULT AND ALERT MESSAGES (CONT)
&DOOWKHWHFKQLFDOVXSSRUWSKRQHQXPEHUOLVWHGRQWKHEDFNFRYHUIRUIXUWKHUWHFKQLFDODVVLVWDQFHRUWRORFDWHDTXDOL¿HGVHUYLFHWHFKQLFLDQ
in your area.
POSSIBLE CAUSES - CHECK/REPAIR DISPLAYED FAULT/ALERT MESSAGE
,I%ORFNHG,QWDNHHUURURFFXUVEHIRUHEORZHUUXQVPDNHVXUH
SUHVVXUHVZLWFKFRQQHFWLRQVDUHFOHDQDQGWLJKW
,I%ORFNHG,QWDNHHUURURFFXUVZKHQEORZHULVUXQQLQJFKHFNIRU
UHVWULFWLRQVLQLQWDNHSLSHLQFOXGLQJLQWDNHDLUFRQQHFWLRQLQWDNHDLU
¿OWHURXWVLGHWHUPLQDWLRQDQGLQOHWPRLVWXUHGUDLQV
2WKHUSRVVLEOHFDXVHV+LJKZLQGFRQGLWLRQVH[FHVVLYHQHJDWLYH
DLUSUHVVXUHLQEXLOGLQJ
8VHDPXOWLPHWHUWRFKHFNWKHFRQWLQXLW\UHVLVWDQFHRILQOHWDLU
SUHVVXUHVZLWFK6ZLWFKVKRXOGEHRSHQQRFRQWLQXLW\ZKHQWKH
EORZHULVRIIDQGFORVHGVKRUWHGZKHQWKHEORZHULVRQ5HSODFH
WKHVZLWFKLIQHFHVVDU\
ADVANCEDBACK
0 days 0 hrs 0 mins ago
Error Code: A7-1201
Blocked Air Intake
Restriction in air intake.
Check intake pipe and
termination for blockage.
Press the Advanced button for
(QVXUHZLUHFRQQHFWLRQVWRXSSHUWHPSHUDWXUHSUREHDUHFOHDQDQG
tight.
8VLQJDWKHUPRPHWHUFKHFNWKHZDWHUWHPSHUDWXUHRIWKHKHDWHU
8VHDPXOWLPHWHUDQGFKHFNIRUFRQWLQXLW\EHWZHHQWKHWZRUHG
ZLUHVRIWKHXSSHUWHPSHUDWXUHSUREH
,IWKHWZRUHGZLUHVDUHRSHQQRFRQWLQXLW\DQGZDWHUWHPSHUDWXUH
LVEHORZ)UHSODFHXSSHUWHPSHUDWXUHSUREH
,IWKHZDWHUWHPSHUDWXUHH[FHHGV)WXUQRIIHOHFWULFSRZHUDQG
JDVVXSSO\DQGFDOO7HFK6XSSRUWIRUIXUWKHULQVWUXFWLRQV
ADVANCEDBACK
0 days 0 hrs 0 mins ago
Error Code: A5- 401
High Temp Limit Exceeded
Energy Cut Off has shut off
water heater due to high tank
temperature.
Press the Advanced button for

Related product manuals