TROUBLESHOOTING
ENGINE DOESN’T TURN OVER
POSSIBLE CAUSE SOLUTION
Low battery voltage Recharge the battery to 12.8 VDC.
Loose battery connections Check all connections and tighten.
Loose solenoid connections Check all connections and tighten.
ENGINE TURNS OVER, FAILS TO START
POSSIBLE CAUSE SOLUTION
Out of fuel Refuel, cycle key to ON position three times for 5 seconds each, then start.
Water is present in fuel Drain the fuel system and refuel.
Old or non-recommended fuel Replace with fresh recommended fuel.