KOKUSAN-DENKI BREAKERLESS FLYWHEEL
MAGNETO TYPE GK 352 (Can't.)
also remained in normal condition.
So,
there
is
no
necessity
to
conduct any adjusting
work
on
the
magneto
if
care
is
given
to
the following points:
4.1
Removing
of
dust and
oil
4.2 Checking
of
connections
of
leads
and couplers
4.3 Checking
of
screw loosening
5.
Inspection and Overhaul
5.1
Flywheel
In ordinary operation no repairs
are
needed.
5.2 Stator
In ordinary operation no repairs
are
needed.
But
when
engines
are
out
of
order
or
do
not
run
or
when a secondary
coil does
not
generate high voltage check the
following
points:
(1) Exciting Coil
Using a tester (Ohm meter) check the
continuity
between
coil plate and
lead
wire (black).
If
resistance measures 23
ohms
it
is
normal.
(2) Pulser Coil
Using a tester check insulation resistance between coil
plate and a
lead
wire
(brown).
If
resistance
measures
co
,
it
is
in normal condition.
Next
check
continuity
between
lead
wire (brown) and lead
wire
(plural-
black and white).
Normal resistance
is
53 ohms.
(3) Lighting Coil
Breaking down
of
coils
is
not
likely
to
occur
so
check
the state
of
soldering and couplers. Test
continuity
be-
tween the stater and the
lead
wire (yellow). Normal
re-
sistance
is
0.35
to
0.45 ohms.
45