26
www.airtouch.net.au
Problem Suggested Action
LED in the
lower right
corner ashes
quickly
No communication between the console and
main module. Check if the AirTouch 2+ App is
running and the wiring.
Disconnect the cable to the touchscreen and
connect it back. Or power o the main module of
the AirTouch 2+ and power it back on in a minute.
LED ashes
slowly (Every
one second)
AC has an error. Either AC is faulty or the
communications between AC and AirTouch 2+
is lost. Call technician to further investigate.
No LED light
No power to the console.
Dampers have
no response
when turned
on or o
Check if LEDs on the main module light up for
relevant zones when the zone dampers are being
turned On/O. If Green/Red LEDs are not activated
for the respective zone, the main module may be
faulty, replace it.
If there is response, there might be a faulty cable
and the cable would have to be replaced. If the
zone is still non-functional then there might be a
faulty damper motor.
Check if the cable from touch-pad to the main
control module is faulty. If it is a faulty cable, then
replace the cable.
Check Grouping and nd out if the right zones have
been assigned to the right groups and have been
turned ON/OFF in Zoning section.
Troubleshooting