EasyManua.ls Logo

Polytec PSV 300 - Page 19

Polytec PSV 300
105 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TTL inputTTL input  (BNC jack)(BNC jack)
TTL input for an TTL input for an external trigger signalexternal trigger signal
Generator outputGenerator output

(BNC jack)(BNC jack)
Output signal of the Output signal of the internal function generator.internal function generator.
Analog inputAnalog input (BNC jack)(BNC jack)
Analog input for the reference signalAnalog input for the reference signal
Analog inputAnalog input

for for the velocity signal (BNC jack)the velocity signal (BNC jack)
Analog input for the velocity signal from the controllerAnalog input for the velocity signal from the controller
Analog inputsAnalog inputs andand (BNC jack)(BNC jack)
Analog inputs for 2 additional reference signalsAnalog inputs for 2 additional reference signals
 Generator outputGenerator output (BNC jack)(BNC jack)
Additional output signal of the internal function generatorAdditional output signal of the internal function generator
 TTL inputTTL input
  
(BNC jack)(BNC jack)
TTL input for an TTL input for an external gating signal.external gating signal.
 TTL outputTTL output   (BNC jack)(BNC jack)
TTL output for special applications, programmable via the optionalTTL output for special applications, programmable via the optional
VisualVisual
®®
Basic Engine PSV-Z-082Basic Engine PSV-Z-082
    
   
The front panel of the junction box for the PSV models -F and -U is The front panel of the junction box for the PSV models -F and -U is shown inshown in
fi
figugurere 3.3.66..
 LL
EDED
The LThe L
EDED
lights up when the junction box is correctly cabled to thelights up when the junction box is correctly cabled to the
controller and the key switch on the controller is turned to position I. Thecontroller and the key switch on the controller is turned to position I. The
LL
EDED
indicates that the junction box is ready to operate.indicates that the junction box is ready to operate.
Control keys for theControl keys for the

, pan, pan
Using these keys the optional pan-tilt stage is panned clockwise (Using these keys the optional pan-tilt stage is panned clockwise (
) or) or
anti-clockwianti-clockwise se ((
) (refer to) (refer tosecsectiotionn 5.45.4). Alternatively it can be controlled). Alternatively it can be controlled
via the software as described in via the software as described in the software manual.the software manual.
Figure 3.6: Front view of the junction box for the PSV models -F and -UFigure 3.6: Front view of the junction box for the PSV models -F and -U

 
 
 



 
