This manual contains important information about the installation,
operation and safe use of this product, and should be given to the
owner and/or operator of this equipment. When installing and using
this electrical equipment, basic safety precautions should always
be followed. Failure to follow safety warnings and instructions in
this manual can result in serious injury and/or damage to your
equipment. Read and follow all warnings and instructions.
● The power supply internally contains live electrical components. There is a danger
of electric shock if opened.
● If the carton or product has been damaged or is wet: do not install the product,
contact your Pool Pro stockist.
● The product must be installed in accordance with AS/NZS 3000 Wiring Standards
and must be installed at least 3.5m away from the pool.
● CHLORINE GAS BUILDUP CAN OCCUR WITH IMPROPER WIRING: To reduce
the risk of personal injury, the power pack is designed so that the electrolytic cell
will only receive power when the pool pump is on. Otherwise, dangerous chlorine
gas build-up can occur. If the pump is not installed to the AC Socket (pump outlet)
on the power pack then the installer must ensure that the electrolytic cell is never
energised when the pool pump is OFF or water is not owing through the unit. A
venturi pipe is installed within the cell housing to eliminate any possible gas build
up, however it is RECOMMENDED that the cell housing be installed horizontally to
create a natural gas trap that acts as a safety device. Installation in any other way
may cause explosion, injury or death if the installer does not allow for gas removal.
● If you perform a backwash manually (without using the Backwash function on the
chlorinator) you must turn the chlorinator’s output down to the lowest percentage
setting via the “Chlor Setting” function.
● The pump rating must not exceed 8amps.
● Salt water may damage electrical components in the power pack.
● We DO NOT recommend the use of valves on the inlet or outlet of the cell housing.
If you do use a valve it is important that the valve cannot deadhead (lock closed)
while the pump is running. It is the installer’s responsibility to ensure some form of
ow control is installed in this instance and it disables the pump.
● Ideal salt levels range between 3000-3500ppm (parts per million). Salt levels
below 3000ppm and above 4000ppm may damage equipment and void any
warranty.
● Do not permit children, or persons with reduced physical, sensory or mental
capabilities to use or perform maintenance on this product. To reduce the risk of
accidents or incidents, service on the unit should only be performed by your local
Pool Pro Professional.
WARNINGS