PH CORRECTIVE MODE (ACID OR BASIC)
The device is configured to regulate the acid mode (make the pH go down). If necessary, you could change in
basic mode (make the pH rise) by using the setting menu :
Your device is now ready.
Important :
For the protection and longevity of equipments of your pool, it is imperative to respect literally the instructions of use
mentioned in this manual. The presence of an amperometric chlorine regulation, of a redox production controller or a pH
regulation do not exempt from the strict respect of the instructions and do not have authority to eliminate the risks and
damages but only to limit them. Indeed, in spite of the smooth running of a control or regulation device, other factors may
cause damage, in particular :
- an insufficient ventilation in case of covered pool (shelter, tarpaulin, cover)
- a maintenance default of analysis probes (calibration, addition of the consumable…)
- manual processing of supplements excessive or not adapted (choc processing…)
- the non-compliance with the instructions of use described in the present user manual
These isolated or organized factors will tend to cause oxidation on all metallic parts and of automatic cover pins and slats,
telescopic shelters and heat exchangers can lead to irreversible deterioration (discoloration) of the pool lining.
Therefore, if the manufacturer’s responsibility was engaged for a malfunction of the control or regulation device, it would be
limited to the repair or the replacement of the product free of charge. Then, it is strongly recommended to check the levels of
chlorine and pH each week with your usual analysis kit.
REACTIVATION
The device has a program which helps you to starting up again your device at the beginning of the season
A/ PH PROBE CALIBRATION
The pH probe is submitted to a reference curve which according to the use of the pool, moves in the time.
For an optimal regulation, it is important to proceed to a calibration every starting up again of the pool or
when changing the probe.
✓ Before proceeding to a calibration, provide you calibration solutions pH7 and 10.
✓ Stop the filtration. Remove accessories holder and stop up by the origin cap.
✓ Put back the filtration on and use the setting menu :