Do you have a question about the PoolPak ComPak HCD 1400 and is the answer not in the manual?
Brand | PoolPak |
---|---|
Model | ComPak HCD 1400 |
Category | Dehumidifier |
Language | English |
Important safety instructions regarding qualified personnel and potential hazards.
Describes the microprocessor control system for maintaining comfort conditions.
Details the dew point control method for dehumidification.
Overview of the microprocessor-based control system.
Explains how the system controls humidity levels.
Mentions the CPCS-PCP controller and RAP for remote access.
Instructions for installing the PCP unit.
Details electrical power supply requirements and connections.
Information on field connections for control wiring.
Explains the economizer system and its operation.
Describes the optional air-cooled condenser and its wiring.
Provides a detailed wiring schematic for field connections.
Provides detailed instructions for pool water piping connections.
General guidance for installing remote air-cooled condensers.
Guidance for qualified mechanics on field-installed piping.
Instructions and calculations for refrigerant and oil charging.
Explains how to access and configure the CPCS-PCP system.
Description of the remote interface unit's functions and display.
Details how to view operational status screens.
How to access and change set points for temperature and humidity.
How to set and adjust pool water temperature.
How to access detailed status information.
Master/slave operation and unit identification.
Parameters for configuring the CPCS-PCP network.
How to change network and local set points.
Accessing and navigating the service menu.
Configuring input/output parameters.
Parameters for configuring installed unit options.
Parameters for configuring compressor operation.
Parameters for air temperature control routines.
Parameters for humidity control routines.
Parameters for water heating control routines.
Parameters for configuring multi-unit network operation.
Configuration parameters related to compressor operation.
Configuration parameters for the economizer system.
Accessing and interpreting the fault history log.
Explanation of fault code numbers for alarm statuses.
Enables manual control of specific system demands for testing.
Allows manual control of digital outputs for testing.
A comprehensive checklist before initial unit startup.
Steps for performing the initial unit startup.
Explains conditions causing compressor shutdown.
Describes how the system handles and displays fault conditions.
Indicates compressor shutdown due to high refrigerant pressure.
Indicates compressor shutdown due to low refrigerant pressure.
Indicates a problem with the CPCS-PCP's EEPROM.
Troubleshooting steps for compressor-related symptoms.
Provides a detailed wiring schematic for field connections.
Checklist for reviewing the general installation of the unit.
Inspection steps to be performed before starting the unit.
Steps to verify proper fan operation after applying power.
Procedure for testing auxiliary air heat functionality.
Steps for starting the compressor and recording initial data.
Procedure for testing the compressor in air reheat mode.
Procedure for testing pool water heating for AW units.
Procedure for testing the air cooling mode.
Verifying correct refrigerant and oil amounts during air cooling setup.