PoolPak HCD 1200 Specifications

General IconGeneral
BrandPoolPak
ModelHCD 1200
CategoryDehumidifier
LanguageEnglish

Summary

Indoor Pool Design

Pool Dehumidification Equipment Choices

Overview of methods for controlling humidity, temperature, and ventilation.

Mechanical Dehumidification Systems

Uses mechanical refrigeration and heat recovery; higher first cost, lower operating cost.

Principles, Functions, and Features

Mechanical Dehumidification System Principles

System overview, vapor compression cycle, and heat recycling for efficiency.

PoolPak System Operation Principles

How the system manages humidity, temperature, and recycles energy for comfort.

Automatic Temperature & Humidity Control

Microprocessor control system sensing and maintaining comfort conditions automatically.

Room Dew Point Control Strategy

Advanced control method for maintaining moisture levels below damaging thresholds.

PoolComPak Unit Operation

Airflow through evaporator, refrigerant cycle, and heat transfer for dehumidification.

ECC-PCP Control System Overview

Micro-processor system for managing pool enclosure humidity and air/water temperatures.

ECC-PCP Humidity Control

Activates compressor based on dew point and directs recovered heat for space/water heating.

Cold Surface Humidity Reset

Sensor measures coldest surface temp to adjust humidity setpoint, preventing condensation.

Networking Multiple PoolComPak Units

Connects up to four units for coordinated control of temperature and humidity.

PoolComPak Features and Options

Lists standard factory-mounted and field-supplied features and system options.

PoolComPak System Selection

System selection based on application type (AW Series vs. HCD Series).

RoofPak Microprocessor Controller

Utilizes ECC-PCP technology with RAP for remote access and BAS integration.

RoofPak Technical Summary

Key performance and dimensional data for RoofPak models.

Performance and Sizing

PoolComPak Performance Data

Detailed performance data for PoolComPak AW units.

PoolComPak AW Performance Summary

Performance summary table for AW series units.

PoolComPak HCD Performance Summary

Performance summary table for HCD series units.

Refrigerant Charge Information

Factory refrigerant R410A charge for units with ACC and WCC.

Remote Air-Cooled Condenser (ACC) Performance

Performance chart for remote ACC models, including piping and electrical data.

Installation

PoolComPak Installation Overview

General requirements for unit placement, piping, and electrical connections.

Unit Power Supply Requirements

Details on fused disconnects, wire sizing, ground connections, and NEC compliance.

ECC-PCP Controls Field Wiring

Description of field wiring for the ECC-PCP system.

Pool Water Piping (AWH/AWV Models)

Installation guidelines, water chemistry, flow rate, and pressure drop for pool water piping.

Field Installed Piping Guidelines

General guidelines for installing refrigerant piping by qualified mechanics.

Refrigerant Piping Guidelines

Material recommendations, brazing, inert gas flow, and support for piping.

Refrigerant Line Sizing

Guidelines for sizing lines to ensure oil carryover and prevent pressure drops.

Refrigerant and Oil Charging

Procedures for charging refrigerant and oil, including sample calculations.

Operation

ECC-PCP Remote Interface Unit (RIU)

Description of the RIU keypad and basic operation.

Set Point Change Menu

How to access and change set points for temperature, humidity, and pool water.

ECC-PCP Network Operation

Master/slave operation, network roles, and status screens.

ECC-PCP Network Configuration Parameters

Configuring network parameters like water temp control, staged dehumidification.

ECC-PCP Service Menu

Accessing the service menu and sub-menus like I/O Configuration.

System Fault History

Information on the last 50 faults for troubleshooting.

Routine Maintenance Overview

Importance of periodic maintenance for equipment life and problem prevention.

Wiring

Field Wiring Diagram

Comprehensive diagram showing field wiring for various components and options.