5. MAINTeNANCe ANd INSPeCTION
5.3 Guide for Poor Heat Gain
POOL WATER IS NOT HEATING UP:
Is the heat pump turned on ?
What is the temperature set too ?
Is there sufficient water flow ?
How long is the heat pump set to run for ?
Are there any water features ?
Does the pool have a blanket ?
What is the ambient temperature ?
Is the condenser covered in ice ?
Are bypass valves closed off ?
NOTE: IF THE CONDENSER IS COVERED IN ICE
Set the parameter 02 to 30 minutes
Set parameter 03 to 0
Set parameter 05 to 15 minutes
5.4 Customer Responsibilities
BEFORE YOU CALL FOR SERVICE read the following points carefully which are your responsibility.
A service charge will be made for service as a result of:
Power not turned on or disrupted
Heat pump not set to run for a long enough period
Heat pump installed incorrectly
Recirculation pump not operating correctly
Controls incorrectly set
Poor water chemistry (Salt Level, pH, etc)
Poor water flow (Check filter is clean/Pump operation/Skimmer free of obstructions and bypass flow is not excessive)
Heat pump being tampered with by unauthorized persons
• Excessive ambient conditions