16
6. LED INDICATOR LIGHT
SAFETY TIP: Using the Power Button to turn the system OFF does not remove power
from the control box. Always disconnect power at the circuit breaker prior to attempting
any service procedure.
Indicator light Working status
Power Located on the Power Button, this LED indicates that the Control
Module is receiving input power when illuminated
Generate This LED is illuminated during normal operation, and indicates
that the system is able to generate chlorine. When ashing, the
pool water is either too hot or too cold for chlorine generation
Super CL Located on the Super CL Button, this LED is illuminated when the
Super CL mode is active. (100% - 24h)
Remote: This part is controlled by a remote control system.
No Flow This LED is illuminated when the Flow Switch has detected no
ow. This causes the Cell to stop generating chlorine. A ashing
LED indicates that the ow is restored, but there will be a 60
second delay before generation is reestablished.
Lo Salt: When this LED is ashing, the salt level is near to its minimum
threshold, which is causing the Cell to operate at low e󰀩ciency.
When this LED is illuminated steadily, the salt level is too low
and Cell has shut down. The salt level must be raised before
operation is restored. See «Adding Salt» for more information.
Hi Salt When this LED is ashing, the salt level is higher than necessary.
When this LED is illuminated steadily, the salt level is too high
and the Cell has shut down. The pool water must be diluted with
fresh water before operation is restored.
Check Cell When this LED is illuminated, Cell e󰀩ciency is greatly reduced,
or it is time for regularly scheduled Cell inspection. When
illuminated, the Cell has stopped producing chlorine. The
Electrolytic Cell should be inspected and cleaned (if necessary).
Remove power from the system, and inspect the Cell. If mineral
build-up is present, clean Cell according to the instructions
on page 19. If after inspection, the Check Cell light is still on
after restoring power to the system, then cleaning is necessary
even if mineral build-up wasn’t immediately visible to the eye. If
illuminated after cleaning, Cell replacement may be necessary.
This light takes priority over any salinity indicators.