EN| 15
EN
4. Use
The system’s settings can be checked and adjusted via the remote control by following these
steps
Step 1 : Keep pressing + until you enter the settings verication mode.
Step 2 : Press
and for see the parameters.
Step 3 : Press
to select the setting to be modied.
Note, some settings cannot be modied. Consult the settings table for further information.
Step 4 : Press and to adjust the setting value.
Step 5 : Press
to set the new value.
Step 6 : Press
to return to the main screen.
WARNING: This operation is used to assist servicing and future repairs.
The default settings should only be modied by an experienced professional person.
4.6 Status values and advanced settings
Paramètres Description
Range
value
Comment
C0
Default temperature(heating mode) 15~40°C 27°C
C1
Température par défaut (mode chauage)+B5:B24 1~15°C 2°C
C2
Power-o memory function 0~1 1(memory)
C3
Exhaust temperature protection setting value 30°C~115°C 110°C
C4
Maximum setting of heating temperature 30°C~60°C 40°C
C5
Minimum setting of heating temperature 5°C~30°C 15°C
C6
Deviation set value of heating up to temperature and stop 0°C~18°C 0
C7
Default temperature(cooling mode) 8~28°C 27°C
C8
Adjustment of temperature dierence for restart(cooling mode) 0°C~15°C 2°C
C9
Deviation set value of refrigeration reaching temperature stop 0°C~18°C 0
C10
Maximum setting of cooling temperature 20°C~35°C 28°C
C11
Minimum setting of cooling temperature 2°C~18°C 8°C
C12
Low ambient temperature protection temperature value -25-20°C -7°C*
C13
High ambient temperature protection temperature value 35-60°C 42°C
C14
Adjustment of temperature dierence for ambient temperature protection 1-10°C 2°C
H0
Defrost auto-activation time 1~240min 30min
H1
Maximum defrost duration 1~25min 8min
H2
Defrost deactivation temperature 1~25°C 20°C
H3
Defrost activation coil temperature -20~20°C -3°C
H4
The temperature dierence between entering the defrosting environment
and the outdoor coil
0~15°C 5°C
H5
defrosting outdoor ambient temperature 0~20°C 20°C