6
Length of Cord in Feet
115V 25 Ft. 50 Ft. 100 Ft. 150 Ft. 200 Ft. 250 Ft. 300 Ft. 400 Ft. 500 Ft.
230V 50 Ft. 100 Ft. 200 Ft. 300 Ft. 400 Ft. 500 Ft. 600 Ft. 800 Ft. 1000 Ft.
0-2 18 18 18 16 16 14 14 12 12
2-3 18 18 16 14 14 12 12 10 10
3-4 18 18 16 14 12 12 10 10 8
4-5 18 18 14 12 12 10 10 8 8
5-6 18 16 14 12 10 10 8 8 6
6-8 18 16 12 10 10 8 6 6 6
8-10 18 14 12 10 8 8 6 6 4
10-12 16 14 10 8 8 6 6 4 4
12-14 16 12 10 8 6 6 6 4 2
14-16 16 12 10 8 6 6 4 4 2
16-18 14 12 8 8 6 4 4 2 2
18-20 14 12 8 6 6 4 4 2 2
Nameplate Ampere Rating
RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS
FUNCTIONAL DESCRIPTION
FOREWORD
MODEL 7529’s versatility - speed range of 8,000 to 23,000 RPM, collet
sizes of
1
/4",
3
/8" (optional) and
1
/2", dual plunge adjustments, and bit size up
to 3
1
/2" diameter - allow it to handle the most demanding routing
applications in various materials.
ASSEMBLY
VACUUM HOSE
A standard 1" vacuum hose can be
attached to the dust port to
connect the tool to a vacuum
cleaner or dust collection system
(Fig.1).
TEMPLET GUIDE INSERT &
OPTIONAL TEMPLET
GUIDES
The templet guide insert is included with the router for use with optional
templet guides. A wide variety of templet guides is available from your Porter-
Cable/Delta supplier for use in pattern and templet routing operations.
1. DISCONNECT TOOL FROM POWER SOURCE.
2. Remove the chip deflector (A) Fig. 2, the three clear dust cover retaining
screws (B) (slotted screw-driver or T20 torx wrench), and the clear dust
cover (C) Fig. 2.
3. With the motor at its highest position, move the plunge locking lever (C)
Fig. 8 to the free motion position by rotating it to the left (in the operating
position) as far as it will go. The lever will lock into position.
Fig. 1