EasyManua.ls Logo

Porter-Cable C3101 - Troubleshooting

Porter-Cable C3101
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18 - ENG
A10382
TROUBLESHOOTING
Pantone 165- Warning orange
Performing repairs may expose voltage sources, moving
parts or compressed air sources, moving parts or
compressed air sources. Personal injury may occur. Prior to attempting
any repairs, unplug the air compressor and bleed off all air tank air
pressure.
PROBLEM
Pressure switch does
not shut off motor when
compressor reaches "cut-
out" pressure.
Pressure switch "cut-out"
too high.
Move On/Auto/Off lever
to the "OFF" position, if
the outfit does not shut off
contact a Trained Service
Technician.
Contact a Trained Service
Technician.
Excessive
tank pressure
- safety valve
pops off.
Tube fittings are not tight
enough.
Tighten fittings where air
can be heard escaping.
Check fittings with soapy
water solution. DO NOT
OVERTIGHTEN.
Air leaks at
fittings.
Air leaks at
pressure switch
release valve.
(if equipped)
Defective pressure switch
release valve.
Contact a Trained Service
Technician.
Air leaks in air
tank or at air
tank welds.
Defective air tank.
Air tank must be replaced.
Do not repair the leak.
Pantone 165- Warning orange
Do not
drill into,
weld or otherwise modify
air tank or it will weaken.
The tank can rupture or
explode.
Air leaks
between head
and valve plate.
Leaking seal.
Contact a Trained Service
Technician.
Air leaks at or
inside check
valve
Check valve seat damaged.
A defective check valve
results in a constant air leak
at the pressure release valve
when there is pressure in the
tank and the compressor
is shut off. Replace check
valve. Refer the "To Replace
or Clean Check Valve" in the
"Service and Adjustment"
section.
CAUSE CORRECTION

Related product manuals