EasyManua.ls Logo

Porter-Cable CMB15 - Hazard: Risk of Falling; Hazard: Risk from Noise; Specifications Overview

Porter-Cable CMB15
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 - ENG
• Donotoperatetheproductwhen
fatigued or under the influence of alco-
hol or drugs. Stay alert at all times.
• Neverdefeatthesafetyfea
tures of this prod uct.
• Equipareaofoperationwith
a fire extinguisher.
• Donotoperatemachinewithmiss-
ing, broken, or un au tho rized parts.
• Neverstandonthecompressor.
HAZARD
RISK OF FALLING
WHAT CAN HAPPEN HOW TO PREVENT IT
• Aportablecompressorcan
fall from a table, workbench,
or roof causing damage to
the compressor and could
result in serious injury or
death to the operator.
• Alwaysoperatecompressorinastable
secure position to prevent accidental
movement of the unit. Never operate
compressor on a roof or other elevated
position. Use additional air hose to
reach high
locations.
HAZARD
RISK FROM NOISE
WHAT CAN HAPPEN HOW TO PREVENT IT
• Undersomeconditions
and duration of use, noise
from this product may con-
tribute to hearing loss.
• Alwayswearcertifiedsafetyequipment:
ANSI S12.6 (S3.19) hearing protection.
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
SPECIFICATIONS
Model No. CMB15
Bore 1.86 inches (47.3 mm)
Stroke 1.26 inches (32 mm)
Voltage/Hz-Single Phase 120/60
Minimum Branch Circuit Requirement 15 amps
Fuse Type Time Delay
Air Tank Capacity (Gallon) 1.5 liters
Approximate Cut-in Pressure 120 PSIG
Approximate Cut-out Pressure 150 PSIG
SCFM @ 40 psig 3.0*
SCFM @ 90 psig 2.0*
*Tested per ISO 1217
Refer to Glossary for abbreviations.