About the Boiler
This is a Floor Standing, Horizontally Fired, Automatic Pressure Jet Oil Boiler.
The boiler can be flued conventionaly or with a kit as a balanced flue.
This boiler is for use with Kerosine or Gas Oil and for use in GB & IE.
About Safety
Installation must be in accordance with the Installation & Service Instructions and the rules in
force.
Leave these instructions with the user for use on future calls.
Statesman
45/50, 50/70, 70/90, 90/110,
System, Flowsure, Flowsure +
Installation & Service Instructions
Question and Answer IconNeed help?

Do you have a question about the Potterton Statesman Flowsure and is the answer not in the manual?

Potterton Statesman Flowsure Specifications

General IconGeneral
BrandPotterton
ModelStatesman Flowsure
CategoryBoiler
LanguageEnglish

Summary

WARNING! - this is about YOUR safety

Technical Data

Health & Safety Information for the Installer & Service Engineer

Essential safety guidelines, hazards, and precautions for professionals.

Boiler Control Panel Wiring Diagram Statesman System

Statesman Flowsure Control Panel Wiring Diagram

Statesman Flowsure + Control Panel Wiring Diagram

Flue Options: STATESMAN

Pre-Installation Requirements

Regulations and Standards

Outlines relevant building regulations, standards, and publications.

Combustion & Ventilation Air for Open Flue Oil Fired Boilers

Clearances Required Around Balanced and Low Level Discharge Flues

Oil Storage Tank & Supply Installations

Fire Valves

Installation & Commissioning

Connecting the Electricity Supply

Standard Boiler Wiring Diagram (Showing Method Of Connecting Various External Controls)

Commissioning

Burner

Step-by-step procedure for burner commissioning.

Boiler and system preparation

Initial checks before starting boiler commissioning.

Set the System Pressure

Completion of Commissioning

Final steps and user advice after commissioning.

Servicing & Maintenance

Servicing

Annual servicing procedures, including burner and boiler checks.

Replacement of Parts

Replacement of Thermostats (Statesman & System)

Replacement of Thermostats (Flowsure/Flowsure+)

Pressure Relief Valve

Controls Assembly And Thermostats

Fault Finding

Burner Does Not Start, Motor Does Not Run

Checklist and actions for troubleshooting start-up issues.

Boiler Starts, No Flame Established, No Oil To Burner

Troubleshooting steps when the burner starts but no flame is established.

Burner Starts, Flame Established But Goes To Lock Out After 15 Seconds

Flame Established But Not Maintained

Other Problems

Flue Kit Options