25
Storage temperature/humidity: -20 to 70
0
C, 70% RH max
Operating temperature/humidity: -10 to 50
0
C, 70% RH max
Pollution degree: 2
DC Voltage 0 to +70 Volts +1 digit
P-P Voltage .............. 0 to +70 Volts
Frequency Response ......... 10Hz to 10kHz (for tone pass
through)
P-P display ........... 15Hz Square Wave
35Hz Sine Wave
DC Voltmeter Mode - Continuity to ground
- First Level - display is enabled less than 20K Ω
- Second Level green LED is enabled less than approx. 650 Ω
- + Peak Detector Response
- Single event capture less than 200mS pulse width
- Repetitive events less than 1mS pulse width
- Peak to Peak Mode ....... 0 to +70 Volts + 1 digit
- 4Hz to over 500kHz Square Wave input
- 4Hz to over 250kHz Sine Wave input
Over Volt Warning
If the probe tip connects to a voltage greater than +70 Volts
the display will show an “Over Volt” warning.
Remove the probe tip immediately to prevent internal damage
to the tool.
Over Load Warning
If the probe is connected to a battery with voltage greater than
34VDC the display will show an “Over Load” warning.
SPECIFICATIONS
WWW.POWERPROBETEK.COM