Page 26 of 41
Close the drain valve by rotating the lever back to the closed position making
sure the lever snaps back down into the detent.
5. Using a filter wrench, remove the old oil filter. Ensure the oil filter gasket does not remain.
6. Apply a thin film of oil to the gasket on the new oil filter.
7. Screw the new oil filter on and tighten by hand. DO NOT use a wrench to tighten the oil filter.
8. Remove the oil fill cap, add new engine oil to bring the oil up to the correct level, and replace cap.
9. Clean up any spilled oil.
10. Dispose of old engine oil and filter according to local regulations.
COOLING SYSTEM MAINTENANCE
The cooling system circulates coolant through the engine where it absorbs excess heat from the engine.
The coolant then flows through the radiator where this waste heat is exhausted to the atmosphere.
Proper maintenance will help prolong the life of your generator set.
Coolant Specifications
It is important to use a high-quality engine coolant. Engine coolant comes in several types. The use of
50/50 mix of an ethylene glycol type of coolant and clean, soft water is recommended for use in this
generator set. The use of proper coolant helps prevent freezing, boil over, and corrosion.
Coolant Mix
(Antifreeze to Water)
Freezing Point Boiling Point
°F °C °F °C
50/50 -34 -37 226 108