6
VOLTAGE TEST
Zero
or
Low Voltage
High
Voltage
Overload
Output
Voltage OK
Replace
AVR
Check Load Distribution
One Voltage Line
may be
Higher than the other
Check AMP
Draw
From equipment
Check
Main Breaker
On GenSet
Check
Gen End
12 VOLT
BATTERY TEST
One Coil
Low Voltage
Both Coils
Low Voltage
Sensing Voltage
Low or None
Replace
AVR
Check
Connections
Check Engine
RPM 1800
Replace Stator
Replace
Stator
Replace
Stator