Troubleshooting
Green LED indicator light doesn’t blink after activation
• Battery is low – change battery
• Batterie fehlt – Batterie einsetzen
Red LED indicator light blinks after activation
Power meter error – turn off and then on. If this is unsuccessful, then contact
suppor t @ power2m ax . de
Power meter does not pair with a head unit
Battery is low – change battery
Batterie fehlt – Batterie einsetzen
Head unit is not in pairing mode – place head unit in pairing mode
Power meter is in standby – activate power meter by rotating the crank.
Transmission is flawed – avoid sources of disturbance such as WiFi networks, microwa-
ves, mobile phones and other active power meters.
Power meter shows no function
Battery is low – change battery
Batterie fehlt – Batterie einsetzen
Operating software is in an undefined state (the power meter has “crashed”) –
Turn off and then on by removing and inserting the battery. If this is unsuccessful,
contact support @ po wer2ma x . de
Power measurements are not plausible
The zero point has changed uncontrollably – during a ride: do a zero point adjustment by
depowering
Water intrusion into the battery compartment
battery cap has not been closed correctly – remove battery and let area dry, insert
battery again and close battery cap
battery cap is damaged or worn – remove battery and let area dry, insert battery again
and close battery cap
power2max NG
Eco
27
English

Table of Contents

Other manuals for Power2max NGeco

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Power2max NGeco and is the answer not in the manual?

Power2max NGeco Specifications

Battery IconBattery
battery life400 hours
battery charge indicator3 x green: 60 - 100%, 2 x green: 40 - 60%, 1 x green: 20 - 40%, 1 x red short: 10 - 20%, 1 x red long: 0 - 10%
Transmission and Accuracy IconTransmission and Accuracy
transmission standardsANT+ Power Only Profile
accuracy±2%
transmitted dataPower, Cadence
Measurement Range IconMeasurement Range
power range10 - 2999 W
torque range0 - 250 Nm