11. Regulator error message
The PowerBox Cockpit/Competition SRS constantly checks both vol-
tage regulators independently of each other. If a fault should occur in
one of these regulators, this warning will appear on the screen:
There are three possible causes for this warning:
- One or both regulators is generating insufficient output voltage or
none at all. This could mean that you are flying with only one regulator
functioning, and for reasons of safety this is not permissible.
- One or both regulators is not functioning, and is passing through the
full battery voltage. This means that the servos and receiver are being
operated on an excessive voltage, which could lead to failures in the
longer term. This malfunction usually occurs after a reversed polarity
connection.
- One battery is plugged in but not switched on. The second battery is
plugged in and switched on. The screen displays the message
REGULATOR MALFUNCTION. This does not indicate a fault!
The
message is a warning, and is intended to remind the user to switch on
both regulator circuits.
In the first two cases please send the device to our Service Department
at the address below, with the completed repair form which you can
download from our website.
Service address:
PowerBox-Systems GmbH
Ludwig-Auer-Straße 5
D-86609 Donauwoerth
Germany