U P S
Uninterruptible Power System
Line Interactive Network UPS
800VA/1000VA
1200VA/1500VA/2200VA
USERS MANUAL
Printed in USA
ABC
Question and Answer IconNeed help?

Do you have a question about the Powercom 1000VA and is the answer not in the manual?

Summary

Important Safety Instructions

Introduction to the UPS

Safety Precautions and Warnings

UPS Presentation and Components

Front Panel Components

Details the indicators and the ON/OFF/TEST/SILENCE button on the front of the UPS.

Rear Panel Components

Describes the various ports and connectors located on the rear of the UPS unit.

UPS Installation Guide

Inspection and Packaging Handling

Guidance on inspecting the UPS upon receipt and handling packaging materials.

UPS Placement Guidelines

Advice on selecting a suitable location for UPS installation regarding airflow and environment.

Connecting Computer Interface

Steps for connecting the UPS to a computer for monitoring and control via software.

Connecting External Battery Pack

Instructions for attaching an optional external battery pack for extended runtime.

Connecting Telephone;Modem Lines

How to connect telephone or modem lines for surge protection through the UPS.

Connecting to Utility Power

Procedure for connecting the UPS to the main AC power source to operate.

Battery Charging Procedure

Information on charging the UPS battery, emphasizing initial charge duration for best results.

Connecting Equipment Loads

How to connect devices to the UPS output receptacles for protection.

Checking Site Wiring Fault Indicator

How to verify the site wiring fault indicator for proper AC power outlet configuration.

UPS Operation Procedures

Powering On the UPS

Steps to power on the UPS and initiate its automatic self-testing sequence.

Powering Off the UPS

Procedures for safely turning off the UPS unit.

Performing a Self-Test

How to initiate a self-test to verify UPS and battery operational status.

Silencing Audible Alarms

How to temporarily silence audible alarms during backup power operation.

Cold Start Functionality

How to start the UPS from battery power without utility input.

UPS Shutdown Mode

How the UPS enters shutdown mode and can be controlled remotely for battery preservation.

UPS Alarm Indicators

Backup Power Alarm

Description of the slow audible alarm indicating the UPS is operating on battery power.

Low Battery Alarm

Description of the rapid audible alarm indicating critically low battery levels.

Overload Alarm

Description of the continuous audible alarm warning of an overloaded UPS.

Replace Battery Alarm

Description of the continuous alarm and LED indicating battery failure or need for replacement.

Software Options for UPS Monitoring

Power Monitoring Software

Information on software for monitoring UPS status and performing orderly computer shutdowns during power failures.

Interface Kits for Monitoring

Details about interface kits needed to connect UPS status signals to computer operating systems.

Computer Interface Port Details

Battery Replacement Procedure

Troubleshooting Common Issues

UPS Storage Guidelines

Standard Storage Conditions

Guidelines for storing the UPS in a cool, dry location with its battery fully charged.

Extended Storage Recommendations

Recommendations for charging the UPS battery during extended storage in varying ambient temperatures.

UPS Specifications

Powercom 1000VA Specifications

General IconGeneral
Frequency50/60 Hz
Operating Temperature0-40°C
Output Power600W
Number of Outlets4
Communication InterfaceUSB