Copyright © 2016 VARO P a g e | 7 www.varo.com
To start the tool squeeze the on/off switch (8).
To stop the tool , release the on/off switch.
If you press the lock-on button (9) while the on/off switch is depressed, the on/off switch is
kept in the operating position.
To release the on/off switch (8) again, press it briefly to and turn the tool off.
The harder you squeeze the on/off switch (8) the faster the tool will operate.
Use lower speeds for starting.
8.2 Forward/reverse lever
The forward/reverse lever (7) is to determine the direction of rotation of the tool.
To select forward rotation, release the on/off switch and push the forward reverse lever to right
(R) side of the tool. To select reverse, push the lever to left (L) side of the tool.
When changing the position of the lever, be sure the on/off switch is released and the motor is
stationary.
9 TECHNICAL DATA
Model
POWX1170
Voltage
230-240 V~ 50 Hz
Power Input
750 Watt
No load speed
0-1050 min-1
Impact rates
0-4900 min-1
Shank style
SDS
Max. drilling capacity
26 mm
13 mm
40 mm
Net weight
4.9 kg
Insulation class
/ II
10 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
91 dB(A)
Acoustic power level LwA
102 dB(A)
ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).
aw (Vibration)
8,7 m/s²
K = 1.5 m/s²
11 MAINTENANCE
Always keep the drill clean.
Do not use corroding agents for cleaning plastic.
Check carbon brushes in the case of excessive sparking.
Keep ventilation channels free.