EasyManua.ls Logo

PowerTec PT3300Ei - Removing from Storage

PowerTec PT3300Ei
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Long Term Storage Cont’d.
c. Use the drain bolt on the carburetor to completely
empty gasoline from the fuel tank and carburetor
into an appropriate container.
d. Replace and tighten the carburetor drain bolt.
6. Turn the fuel valve to the “OFFposition.
7. Remove the spark plug and pour about a tablespoon
of oil into the cylinder. Crank the engine slowly to
distribute the oil and lubricate the cylinder.
8. Reattach the spark plug and spark plug cap.
9. If the generator includes a battery, disconnect and
charge according to Generator Battery.
10. Clean the generator according to Generator
Maintenance.
11. Store the generator in a cool, dry place out of direct
sunlight.
MAINTENANCE AND STORAGE
Generator exhaust contains odorless and colorless
carbon monoxide gas.
To avoid accidental or unintended ignition of your
generator during periods of storage, the following
precautions should be followed:
When storing the generator make sure the engine
switch and fuel valve are set to the “OFF”
position.
If your generator includes a battery, disconnect
according to the Generator Battery section.
DANGER
If the generator has been improperly stored for a long
period of time with gasoline in the fuel tank and/or
carburetor, all fuel must be drained and the carburetor
must be thoroughly cleaned. This process involves
technically advanced tasks. For assistance please call
our Technical Support line. If the fuel tank and
carburetor were properly emptied of all fuel prior to the
generator being stored, follow the below steps when
removing from storage.
1. Add fuel to the generator according to Add Fuel.
2. With the engine switch in the “OFF” position,
turn the fuel valve to the “ONposition. After 5
minutes check the carburetor and air lter areas for
any leaking gasoline. If found, the carburetor will
need to be disassembled and cleaned or replaced.
If no fuel leaks are found, turn the fuel valve to the
“OFFposition.
3. Check oil level and add clean, fresh oil if needed.
4. Check and clear air lter of any ob
structions such
as bugs or cobwebs. If necessary, clean according
to Air Filter section.
5. If the generator includes a battery, connect
according to Connect the Battery
6. Start the generator according to Starting the
Engine.
Removing from Storage
18.
www.powertec.net.nz
PT3300Ei
3300W DIGITAL
INVERTER GENERATOR

Related product manuals