4 5333V111-UK
Electrical specifications
Specifications range:
-40°C to +85°C
Common specifications:
Supply voltage, DC
Standard .................................................................. 8...35 V
CSA, FM, ATEX, IECEx & INMETRO ................ 8...30 V
Internal consumption ............................................. 25mW...0.8W
Voltage drop .............................................................. 8 VDC
Warm-uptime ............................................................ 5 min.
Communications interface ................................... LoopLink
Signal / noise ratio .................................................. Min. 60 dB
Response time (programmable) ......................... 0.33...60 s
Signal dynamics, input ........................................... 19 bit
Signal dynamics, output ....................................... 16 bit
Calibration temperature ........................................ 20...28°C
Accuracy, the greater of general and basic values:
Order: 5333
General values
Input type
Absolute
accuracy
Temperature
coefficient
All ≤ ±0.1% of span ≤ ±0.01% of span / °C
Basic values
Input type
Basic
accuracy
Temperature
coefficient
RTD ≤ ±0.3°C ≤ ±0.01°C/°C
Lin.R ≤ ±0.2 Ω ≤ ±20 mΩ / °C
EMC immunity influence ........................................... < ±0.5% of span
Type Version
5333 Standard : A
CSA, FM, ATEX, IECEx & INMETRO : D