Configuration / operating the function keys
Documentation for routing diagram.
In general
When configuring the display you are guided through all parameters, you can choose the settings which fit the application.
For each menu there is a scrolling help text which is automatically shown in the display, this starts after 5 seconds if no key
has been activated.
Configuration is carried out by using the 3 function keys.
1 will increase the numerical value or choose the next parameter.
2 will decrease the numerical value or choose the previous parameter.
3 will accept the chosen value and end the menu.
If a function does not exist in the display all parameters are skipped to make the configuration as simple as possible.
Once the configuration has been entered the display will show “----.
Pressing and holding 3 will return to the previous menu or return to the default state (1.0) without saving the changed values
or parameters.
If no key is activated for 2 minutes, the display will return to the default state (1.0) without saving the changed values or
parameters.
Further explanations
Fast setpoint adjustment and relay test: These menus allow you to change the set point quickly and to check the operation
of the relays.
Pressing 1 and 2 at the same time will change the state of the relay – this change is indicated by the diodes on the display.
Pressing 3 will save the set point change.
Holding down 3 for more than 0.5 seconds will return the unit to the default state without changing the set point.
Password protection: Using a password will stop access to the menu and parameters. There are two levels of password
protection. Passwords between 0000…4999 allow access to the fast set point adjustment and relay test. (Using this
password stops access to all other parts of the menu). Passwords between 5000…9999 stop access to all parts of the menu,
fast set point and relay test. (Current set point is still shown). By using the master password 2008, all configuration menus are
available.