INVERTER GENERATOR – P2000i
15
1. Turn off any connected electric devices and stop the
engine.
2. Reduce the
total wattage
of connected electric devices within
the
rated
output.
3
. Check for blockages in the cooling air inlet and around
the
contro
l
unit.
lf any
blockages
are found remove
them.
4. After
checking, restart
the
engine.
NOTE
The Overload Alarm may come on for a few seconds when first using electrical devices that
require a large starting current, such as a compressor, pump, or refrigerator.
This is normal
behavior it is not a malfunction.
Low
Oil Alarm
(
Red)
When the engine oil falls below the required
level the
Low
Oi
l
Alar
m
will
come on and the engine will stop automatically. The engine will not restart
until oil is added to the unit to bring it up to the appropriate level.
NOTE
When starting the unit, if the Low Oil Alarm light flickers and the engine will not start, you
will need to add engine oil before attempting to restart the engine.
only be operated on a level surface. DO NOT operate the generator on
loose ground or obvious inclines. The low oil shutdown feature may be prematurely
activated in these cases causing the engine to not start.
Engine
Switch
The Engine Switch controls the
ignition switch.
Th
e
switch must be in the
“I”
position to start the
generator. Switching
to
the
“O”
position stops the
engine and
will
not allow the engine to be
restarted.