INVERTER GENERATOR – P2000i
25
2. Prior to powering tools and equipment, make sure the generator's rated
voltage, and amperage capacity (220/230V AC @ 7 AMPs, 12V DC @ 8
AMPs) is adequate to supply all electrical loads that the unit will power. If
powering exceeds the generator's capacity, it may be necessary to group
one or more of the tools and/or equipment for connection to a separate
generator.
3. Once the generator is running, simply connect the power cords of
220/230 volt AC powered tools and equipment into the 220/230 volt AC
dual outlets and/or the power cord of a 12V DC powered tool to the DC
terminals.
4. DO NOT connect 3-phase loads to the generator.
5. DO NOT connect 60Hz loads to the generator.
6. DO NOT overload the generator.
NOTE
4.4 Parellel Connection within 2 generator
Performance: increase output through the parallel connection way within 2
sets of P2000i inverter generators.
Operation Guide:
1. 2 sets of P2000i inverter generators needed
Attention: generators are power off, without any loading equipments and
cable sockets.