Diagram 5.5 - Photo Optic Target
16. If the readings in step 15 are not correct, replace the home switch.
17. If the readings in step 15 are correct, carefully check the wiring from the home switch to the
J8 connector on the lower PCA. Ensure that the wiring and connector are intact and that the
wiring is not nicked or cut. Replace or repair the wiring if necessary.
18. If the home switch wiring is good, replace the lower PCA.
19. If you have performed all of the above tests and the magnetic resistance system still does
not function properly, call Precor Technical Support.
20. If necessary set the on/off switch in the on position. Operate the EFX, when the timer starts
to count press the RESISTANCE
s key. If the display does not indicate that the resistance
level has been changed, test the key pad per procedure 5.2.
21. If the display indicates that the resistance level has been changed, but the resistance
assembly did not move and/or an error 54 occurred, skip to step 14.
Photo Optic Target