Procedure 6.18 - Replacing the Eddy Current Magnet
Assembly
Removing the Magnet Assembly
1. The resistance level must be at level 0 when this procedure is performed. If necessary
operate the unit and set the resistance level at 0 and then proceed with step 2.
2. Set the on/off switch in the “off” position and disconnect the power adapter from the EFX.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
3. Remove the rear covers as described in Procedure 6.1.
4. Attach an anti-static wrist strap to your arm, then connect the ground lead of the wrist strap
to the EFX frame.
5. Remove the shield from the lower PCA.
6. Disconnect the cables from the lower PCA (See Diagram 6.5).
7. Remove the screws that secure the lower PCA, remove the lower PCA.
8. Grasp the target disk and carefully pull it off of the gear motor extension shaft.
9. Remove the screws that secure the lower PCA mounting bracket, remove the lower PCA
mounting bracket. (See Diagram 6.15).