EasyManua.ls Logo

Precor EFX 885 - Procedure 3.6 - P80 Systems Tests

Precor EFX 885
171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EFX 885, 835, 825
Service Manual 20039-166
Page 13
©2011 Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Procedure 3.6 P80 Systems Tests
1. Refer to Procedure 3.1 Settings, to access the Equipment Usage menus.
2. The systems tests allow you to check specific functions of the equipment.
3. To select a Systems Test touch on an item in the Systems Test menu.
Systems Tests
Test
Equipment
Description
Auto Stop Test
TRM Only
1. Touch Auto Stop Test, then Touch START.
2. The Auto stop test will start the belt at 1 mph; count will be reset to 0, and then
count up with each step.
3. Touch STOP to end the test. Touch BACK to exit to Systems Test.
Belt Speed Test
TRM Only
1. Touch Belt Speed Test, then Touch START.
2. The belt will start a 0.5 mph, using the machine control paddle to increase by 0.1
mph increments. The console will display motor current as the belt speed
increases or decreases.
3. Touch STOP to end the test. Touch BACK to exit to Systems Test.
Incline Test
TRM Only
1. Touch Incline Test, and then Touch START.
2. Use the machine control paddle to change the lift. The console will display the
analog to digital (A/D) incline position number and the incline position in
percent of incline.
3. Touch STOP to end the test. Touch BACK to exit to Systems Test.
AMT Stride Position Test
AMT Only
1. Touch AMT Stride Position Test and then Touch START.
2. The High, Low and Dynamic positions will be displayed. The low position display
shows the lowest position reading achieved during the test. The high position
display shows the highest position reading achieved during the test. The
dynamic position display changes with current stride position. Stride on the
AMT to the maximum horizontal movement in both directions. At maximum
stride length the low stride display should read 0 and the high stride display
should read 40.
3. Touch STOP to end the test. Touch BACK to exit to System Tests.
Brake Test
AMT, RBK,
UBK, EFX
1. Touch Brake Test, then Touch START.
2. Use the machine control paddle to change the resistance up and down. The
resistance changes will be displayed in power bits.
3. Touch STOP to end the test. Touch BACK to Systems Test.