EFX 885, 835, 825
Service Manual 20039-166
Page 61
©2011 Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Press the BACK key to exit the U-
BOOT SW display.
U-Base SW
Use the , keys to move to
move to HOUR METER.
Press the OK key.
The software part number will be displayed as XXXXX-XXX.
Press the BACK key to exit the U-
BASE SW display.
Lower SW
Use the , keys to move to
move to LOWER SW.
Press the OK key.
The software part number will be displayed as XXXXX-XXX.
Press the BACK key to exit the
LOWER SW display.
Metrics Board SW
Use the , keys to move to
move to METRICS BOARD SW.
Press the OK key.
The software part number will be displayed as XXXXX-XXX.
Press the BACK key to exit the
Metrics BOARD SW display.
Serial Number
Use the , keys to move to
move to SER. NUMBER.
Press the OK key.
The serial number will be displayed. The serial number may be incorrect or
not displayed if the upper PCA has been replaced.
Press the BACK key to exit the SER.
NUMBER display.
Usage log
Use the , keys to move to
move to USAGELOG.
Press the OK key.
A message will scroll describing the program, the number of times and the
number of minutes the program was used.
Use the , keys to move through
the list of programs
Press the BACK key to exit the
USAGELOG display.
Error Log
Use the , keys to move to
move to ERROR LOG.
Press the OK key.
The quantity of errors in the log will be displayed.
Press the OK key.
The most recent error will be displayed first.
Use the , keys to move through
the list of errors.
The error messages will list the error name, the odometer reading (Strides)
when the error occurred and the hour meter when the error occurred.
If you wish to BACK the error log,
press and hold the QUICK START
key.
The message HOLD TO BACK ERRORS will be displayed. The error log will be
cleared when the message NO ERRORS is displayed.
Please note that the ERROR LOG may also be accessed at any time by
pressing and holding the BACK key for four seconds. If the error log does not
contain any errors, the message STUCK KEY will be displayed.
Press the BACK key to exit the
ERROR LOG display.
Press the PAUSE key to exit the
DIAGS-INFORMATION DISPLAY.