3
UNIT FEATURES CONTINUED
• Unit Configuration – There are m an y di fferent
configuration possibilities, through both dipswitches
and the digital keypad, that allow you to configure
the unit for your exact application. See section on
unit configuration for more details. Following are the
configurationselections thathavenotpreviouslybeen
mentioned:
• _For_C – The unit can display in either _For_C
• In door Temperatu re S ensor B iasing – Optimize
the room temperature sensor reading to your exact
application (one for cooling and another forheating)..
• E merg en cy Heat (for H ea t Pump O nly ) – Disable
the compressor during heating mode operation (heat
onl y w it h Electri c Heat ).
• Disp l a y S etp o i n t OR Roo m Temp eratu re -- T h e
unit can be configured to display the room
temperature OR setpoint only, during heating and
cooling modes. See section on unit configuration for
more details.
• Limit the Setpoint Range -- The unit can be
configured to limit the controlling setpoint range.The
display will always show the complet e setpointrange,
but the controlling setpoint will be limited to the
configuredminimumandmaximumsetpointselect ed.
See section on unit configuration for more details.
• Energy Managemen t – Sometimes known as
Front Desk Control, an input is provided so that t he
unit can be manually disabled from a different
location. If the unit detects 24vac on this input, it will
automatically turn itself off. If no voltage is detected
on the input, t he unit will run normally.
• Wall Th ermostat Control –Awiredwall
thermostat can be connected to the unit. If it is, the
unit must be configured to disable the keypad. See
section on wired inputs and unit configuration for
more details.