17/24 Operation Mc Rain Plus
DORW2090 07.01.16
6. Maintenance
The unit includes components which must be inspected or maintained.
In your own interest please follow the specified intervals of inspection and maintenance
work as well as the working sequences.
• Inspections can be carried out by the user of the system!
• Only a qualified installer should maintain and repair the system!
Inspektion and maintenance of the McRain Plus:
Floating valve
Inspection: Check for correct opening and shutting (sealing) and free movement of the
floating part, as well as proper sealing of the level sensor.
Time: every 6 months
Carried out by: user / owner
Service
Inspection: Exchange the level sensor
Time: Only necessary if faulty
Carried out by: Installation company / manufacturer
Controls
Inspection: Testing the functions (chapter 4 and.5)
Time: every 6 months
Carried out by: user / owner
Pump including Flow control
Inspection: pressure loss, leakages, pumps and flow noises, as well as the operations tests.
For this press the key “Restart” on the flow control unit. (chapter.5)
Time: every 6 months
Carried out by: user / owner
Service
Inspection:
replace mechanical seals/bearings
Time every 10,000 operating hours or 10 years, or by signs of wearing
Carried out by: Installation company or manufacturer
Maintenance
Floating switch
Inspection:
check correct installation (see installation instruction Mc Rain Plus chapter8)
check cables for wear and damage
Time: in connection with the control of the collecting tanks
Carried out by: user / owner