The McRain Plus does not operate on automatic?
The cable between the McRain Plus and the float switch in the collecting tank has a short circuit,
this means both wires are in contact, for example – water got into the extension the extension
coupling.
Check the cable, if applicable, check extensions to the cable for water infiltration.
An overflow is detected (water outlet DN70 outlet pipe) on the McRain Plus?
The floating element of the float switch is pushed against the inner wall of the McRain
Plus.
Straighten the floating valve.
The floating valve in the McRain Plus is dirty?
Set the controls.
of the McRain Plus to manual. Open an outlet connection and let the pump run for approx. 1
minute. In this way it tries to clean the valve from impurities.
CAUTION!
If the above procedures do not clear the fault, please contact customer services.