6-6 STARTING AND STOPPING PROCEDURES
PA1633 X3-45 Commuter Operator’s Manual
BOOSTER BLOCK LOCATION
ENGINE PROTECTION SYSTEM
The engine protection will automatically derate
or stop the engine when certain engine
conditions reach a critical stage.
In the event of a serious fault, the red STOP
telltale light comes on and an audible alarm will
sound if the engine is running.
An illuminated STOP telltale light indicates a
serious problem has been detected, and the
driver must respond immediately to the problem.
The vehicle must be safely pulled off the road
and stopped. In some instances, the engine
must be switched off immediately.
AUTOMATIC ENGINE SHUTDOWN
Prior to an actual automatic shutdown, the
engine will automatically derate, go to idle, and
then stop as the vehicle speed gets below 2
mph.
The engine shutdown protection will
automatically derate and stop the engine when
one or more of the conditions listed below
reaches a critical point:
High engine coolant temperature
High engine oil temperature
Low engine oil pressure
High crankcase pressure (rate of change)
After the automatic engine shutdown sequence,
the engine may be restarted. To do so, turn the
ignition switch to the OFF position during 7
seconds and then turn it back to ON. However, it
will only operate for 30 seconds unless the
problem is resolved.
Use this function sparingly and in order to move
the vehicle to a safe parking place only.
Excessive use may result in severe engine
damage.
WARNING
Failure to take necessary action when the
STOP telltale light is on can ultimately result in
automatic engine derate and shutdown.
IDLE SHUTDOWN TIMER
The idle shutdown timer is programmed to shut
down the engine after 15 minutes of engine
idling time.
The engine will shut down at the set time under
the following conditions:
Vehicle speed is 0;
Engine is running at normal or fast idle
speed;
The engine coolant temperature is above
120°F (49°C);
The temperature inside the vehicle is
between 59°F (15°C) and 81°F (27°C);
The parking brake is applied;
The transmission is in neutral (N);
The wheelchair lift system is not in use;
Pressing the fuel pedal will prevent engine
shutdown and restart countdown.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PREVOST X3-45 COMMUTER 2018 and is the answer not in the manual?

PREVOST X3-45 COMMUTER 2018 Specifications

General IconGeneral
CategoryBuses
ManufacturerPrevost
ModelX3-45 Commuter
Year2018
Length45 ft
Width102 inches
EngineVolvo D13
Horsepower435 hp
TransmissionAllison B500
Fuel TypeDiesel
GVWR54, 000 lbs

Related product manuals