EasyManua.ls Logo

PRIMERGY TX300 S3 - 7 Troubleshooting and Tips; 7.1 Power On Indicator Remains Unlit

Default Icon
125 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TX300 S3 Operating Manual 79
7 Troubleshooting and Tips
V CAUTION!
Observe the safety information in the “Safety” manual and in the chapter
“Hardware Installation” on page 31.
If a fault occurs, attempt to resolve it using the measures described:
– in this chapter,
– in the documentation for the attached devices,
– in the help systems of the software used.
If you fail to correct the problem, proceed as follows:
Ê Make a list of the steps performed and the circumstances that led to the fault.
Also make a list of any error messages that were displayed.
Ê Switch off the server.
Ê Contact our customer service team.
7.1 Power On Indicator Remains Unlit
The power-on indicator remains dark after you switch on your device.
Power cable incorrectly connected
Ê Make sure that the power cable(s) is/are correctly connected to the server
and the grounded socket(s).
Power supply overloaded
Ê Disconnect the server power plug(s) from the power socket(s).
Ê Wait a few seconds before you plug it/them into the grounded socket(s)
again.
Ê Switch on your server.

Table of Contents