The mixing of the stock solution tank requires an independent mixing device, which can set the
daily timing mixing function and manually sta/stop the mixing.
Irrigation Priority (system default): Prioritize
irrigation during operation, unless the water level reach-
es the lower limit or forced irrigation causes damage to
crops, such as: EC overrun, pH overrun and water
temperature overrun, under these abnormal conditions
the system will automatically Stop irrigation, and resta
irrigation after the abnormal condition is removed.
Feilizer distribution priority: Once EC or pH is
triggered during the irrigation plan, irrigation will be
stopped, feilizer distribution will be given priority, and
the target value will be reached within the specied
feilizer distribution time. This function is suitable for
users with high requirements for EC and pH range. If the
system is powered o and restaed, as long as the EC or
pH does not reach or exceed the target value, the system
will also stop irrigation.
IRRIGATION
Click [IRRIGATION] to enter the irrigation settings:
There are three modes of irrigation, namely automatic and manual stop and manual test.
Auto Cycle:You can set the opening time, closing time, and cycle eve day.
Auto Timer:Switching time and daily cycle can be set. Up to 10 groups of timers can be set.
Soil Moisture:The d humidity of the substrate is triggered, and irrigation is staed when it is
less than the target value.
Manual OFF:When turned o, does not enter the automatic setting.
15