20 of 24 | English English | 21 of 24
Heat Exhaust Pipe Cleaning
1. Remove the heat exhaust pipe from the rear of the
appliance and the respective window sealing assembly.
Allow to cool.
2. Use a soft, dry cloth to clean away any dust, or debris.
3. Return the heat exhaust pipe.
STORAGE
―
For long-term storage:
1. Empty the water tank and leave both the continuous and bottom drainage caps and
drainage plugs off and unplugged.
2. Run the appliance in fan-only mode on the low fan speed setting for 12 hours to allow the
interior of the appliance to fully dry.
3. Turn off the appliance, replace both the continuous and bottom drainage caps and
drainage plugs, and unplug the power cord.
4. Remove the heat exhaust hose.
5. Remove the batteries from the remote control.
6. Ensure the appliance and water tank are clean and dry before storage.
7. Do not kink or wrap the power cord and plug around the appliance, as this may cause the
insulation to weaken or split, particularly where it enters the appliance.
8. Store the appliance in a safe, clean and dry place, away from direct sunlight and out of
reach of children when not in use. To store your product, we recommend using the original
or a similar sized box.
SAFETY FEATURES
―
Anti-Frost Protection
If the internal pipe temperature drops too low the unit will pause. The display will show E4 and the
appliance will initiate anti- frost protection rendering the control panel buttons inactive, apart from
the power button. Once the internal pipe temperature has warmed to above 8°C (46.4°F) the anti-
frost protection will cease, and the appliance will return to operating at the chosen settings.
Compressor Delay Protection
To protect the compressor, apart from when the appliance and compressor are activated for the
first time after being turned on via the power button, there will be a three-minute delay between
every occurrence of the compressor turning off and on.
TROUBLESHOOTING
―
Please contact a professional serviceman without delay in the following situation.
Note: when abnormal situations occur, turn off the machine and pull out the plug, then contact
with a professional electrician for help.
Problem Cause Solution
The unit doesn’t work
No display Reset the circuit breaker on
the Units cord
The Full Water Tank symbol
is lit. Or the display panel
displays “FL”
Turn the power off and
unplug the unit, then drain the
water tank with the method
outlined in this manual. Plug
the unit back in
Time OFF function has started The unit can be restarted
three minutes after being
turned off
The unit starts frequently
Direct Sunlight Move the unit out of direct
sunlight
Doors and windows are open/
there are many heat sources
in the room
Close doors and windows
and remove heat sources
The filter screen is dirty Clean the filter screens or
replace them
The Air inlet or air outlet is
blocked
Remove the blockage
Loud noise coming from the
unit
The machine is not put on flat
ground
Place it on flat and stable
ground
The compressor doesn’t work
Compressor time-delay
protection turns
Wait for three minutes, then
restart the machine after the
temperature reduces