M-62-04 SHC-1.4-61RQH-R-0070 Manual
Revision - Date: 02 – 09/23/2015
15
OPERATION:
During operation, the surface temperature of the
heater may exceed 40°C. Avoid contact- serious
personal injury may result.
Start Up Procedure:
1) Start process fluid flow. Allow solution to flow for several minutes to remove any air from
the heating chamber.
2) Turn on the main power to the system.
3) Turn on the control module.
4) Verify proper reading of the process temperature.
5) Engage the control system’s safety relay, if applicable.
6) Turn on the heater.
Shut-Down Procedure:
The heater chamber may contain process
solution or residue. This material should be
handled with the same care and precautions as
any process solution.
1) Turn off electrical power to the heater.
2) Allow heater to cool. The Inline heater may be damaged if the heater is allowed to
operate in air or if residual heat is not allowed to dissipate before draining. Before the
chamber is drained, the outlet temperature must be allowed to cool to within 1
C of the
inlet temperature. Then, wait an additional 10 minutes.
3) Turn OFF process fluid flow through the Heater.
4) Turn OFF process controller.
5) Turn OFF Main Electrical Power.
6) For extended shut down periods, drain the system.